SKU: 73184847900

DA-2 Dry Eye Analyzer

Sale price$1885.92 Regular price$2095.47
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 10 - Jul 15

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

DA-2 Dry Eye Analyzer*Special Promo Free Meibomian Gland Forceps and 3 USB Dry Eye Mask Samples until 6 30 26* Why is the DA 2 Dry Eye Analyzer the Best Option? The DA 2 Dry Eye Analyzer, developed by OcuRx, is a compact, multi functional diagnostic device specifically designed for efficient, non invasive assessment of dry eye disease (DED) and meibomian gland dysfunction (MGD). Priced at just $4,700, it stands out as an exceptional value in a market where similar tools

*Special Promo - Free Meibomian Gland Forceps and 3 USB Dry Eye Mask Samples until 6/30/26*

Why is the DA-2 Dry Eye Analyzer the Best Option?

The DA-2 Dry Eye Analyzer, developed by OcuRx, is a compact, multi-functional diagnostic device specifically designed for efficient, non-invasive assessment of dry eye disease (DED) and meibomian gland dysfunction (MGD). Priced at just $4,700, it stands out as an exceptional value in a market where similar tools often exceed $10,000 or even $20,000, making it ideal for eye care professionals looking to enhance their practice without a massive upfront investment.

Our Multi-Functional Dry Eye Analyzer fully supports 8 dry eye testing functions, including NiBut (Non-Invasive Break-Up Time), Lipid Layer Imaging/Video, Meibomian Gland Opening, TMH (Tear Meniscus Height), Meibography (Infrared and Color), Corneal Staining, Anterior Segment Imaging/Video and Red Eye Measurement.

The DA-2 is designed to be user-friendly providing quick and accurate results. It can be used handheld, on a standard chin rest/base to use in the pre test room or attached to a slit lamp. The entire dry eye examination can be completed in about five minutes. A complete analysis and evaluation is provided at the end of testing. The DA-2 brings two slit lamp attachments that are compatible with all systems.

Advanced Dry Eye Diagnosis Includes: 

1. NiBUT (Non-Invasive Tear Break-Up Time) is a cutting-edge diagnostic test used to evaluate tear film stability, a critical factor in diagnosing dry eye syndrome. Unlike traditional methods, NIBUT is a noninvasive procedure that avoids using dyes or fluids, making it comfortable and highly accurate. This preferred test measures the time in seconds between a patient’s last blink and the first appearance of a dry spot in the tear film, as observed through specialized video analysis.

2. Lipid Layer Imaging and Video - Lipid layer measurement refers to evaluating the lipid layer's thickness, structure, or stability on the surface of the tear film in the eye.

3. Gland Opening - Gland opening measurement refers to assessing the orifices or ducts of the meibomian glands, which are located along the edges of the eyelids. Measuring the state of the gland openings helps in diagnosing conditions like meibomian gland dysfunction, this test can also be used for color meibography.

4.Tear Meniscus Height (TMH) measurement - Refers to evaluating the tear meniscus height, the thin strip of tear fluid that forms at the junction between the eyeball and the eyelids. This measurement is commonly used to assess tear volume and is an essential diagnostic tool for evaluating conditions such as dry eye disease and ocular surface disorders.

5. Meibography - Meibography is an imaging technique used to visualize and evaluate the structure of the meibomian glands, which secrete oils (meibum) that form the lipid layer of the tear film. This test is critical in diagnosing meibomian gland dysfunction (MGD), one of the leading causes of evaporative dry eye disease.

6. Corneal Staining - Corneal staining is a noninvasive procedure that uses special eye drops to highlight areas of damage or dryness on the cornea, the clear front surface of the eye. By identifying these issues, optometrists can accurately diagnose and treat conditions like Dry Eye Syndrome, Corneal Abrasions, and Corneal Ulcers.

7. Red Eye Measurement - Red eye measurement assesses the severity, extent, and underlying causes of ocular redness, which is often a sign of inflammation or irritation in the eye. Redness in the eye occurs when blood vessels on the eye's surface (particularly in the conjunctiva or sclera) become dilated due to various factors, including infection, allergies, dry eye, trauma, or other eye conditions. This test also works well for resolution 12x anterior segment imaging.

8. Anterior Segment Imaging and Video -

Discover the transformative power of anterior segment imaging and video. This advanced diagnostic technology provides high-resolution images and real-time video of the eye’s anterior segment, including the cornea, iris, lens, and anterior chamber, enabling precise diagnosis and treatment planning.

Detailed imaging detects subtle abnormalities in conditions such as dry eye, corneal dystrophies, and anterior uveitis, thereby improving diagnostic precision.

TESTIMONIAL

“DA-2 Dry eye analyzer has been a game-changing, portable, and affordable device that revolutionizes the diagnosis and management of MGD-related dry eyes. With its high-quality imaging, user-friendly interface, and non-invasive nature, the DA-2 simplifies the diagnostic process and enhances patient outcomes. It's easy to use and requires minimal space. I highly recommend the DA-2 to eye care professionals for efficient MGD diagnosis and management." 

- Dr Mario Carcamo

-Includes SPEED and OSDI Assessment Integrated into the program

-Includes PDF or JPEG download of comprehensive report

30-DAY MONEY BACK GUARANTEE

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 73184847900

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.7 ★★★★★
Based on 2271 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
R
Verified Purchase
Ryan J
Charlottesville, US
★★★★★ 4
Inexpensive and Nice Quality
Size: Standard (Pack of 2), Style: Medium, Configuration: Hometextile
I was hoping there would be more of a firmness to these pillows, however they are more soft than I was expecting them to be. Id recommend these pillows for someone who wants a fairly non firm pillow.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 18, 2026
D
Verified Purchase
Damian_yanay
Chelsea, US
★★★★★ 5
Almohadas
Size: Standard (Pack of 2), Style: Medium, Configuration: Hometextile
I love them, they are super comfortable and perfect for a perfect relaxed and peaceful sleep
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 5, 2026
L
Verified Purchase
Lily
Whiting, US
★★★★★ 5
Soft and Comfortable Pillow
Size: Standard (Pack of 2), Style: Medium, Configuration: Hometextile
This pillow has a soft feel with a nice balance of comfort and support. It fluffs up well after opening and maintains its shape throughout the night. The cover feels smooth, and the overall construction appears well made. A comfortable option for side and back sleepers looking for a plush sleeping experience.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 10, 2026
B
Verified Purchase
Beth
Boise, US
★★★★★ 3
Not for side sleepers
Size: Standard (Pack of 2), Style: Medium, Configuration: Hometextile
These pillows are quite soft and flat, and offer very little support. I sleep on my side and can't use these pillows. I don't know why they're recommended for side sleepers.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 31, 2025
S
Verified Purchase
Sharon Shelton
Lowell, US
★★★★★ 5
Good head and neck support
Size: Standard (Pack of 2), Style: Medium, Configuration: Hometextile
Soft yet firm, comfy, no toxic smell.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 8, 2026

recommand products